105 – Development Data On/Off
Use this command to enable development data information if you are having
trouble getting commands accepted. Invalid commands generate debug
information that enables you to determine the source of the command rejection.
Common reasons for input command rejection are invalid checksum or
200 – PowerManagement
The table below contains the values for the following example to set the receiver
to Adaptive Trickle Power mode:
$PLSC,200,2,300,1000,300000,30000*0E
parameter out of specified range.
The table below contains the values for the following example:
1. Debug On
Name
MID
Mode
Example
$PLSC,200
2
Units
Message ID
See Table 23
Description
2. Debug Off
$PSRF105,1*3E
$PSRF105,0*3F
OnTime
300
(200 - 900)
mS
Must be > 200mS and a multiple of 100 (if
not, it is rounded up to the nearest multiple
of 100).
Name
Example
Units
Description
LP Interval
1000
(1000 -
mS
Must be an integer value > 1000 and <10000.
Message ID
Debug
$PSRF105
1
PSRF105 protocol header
0=Off, 1=On
10000)
When Adaptive Trickle Power is enabled,
Checksum
<CR><LF>
*3E
End of message termination
300000
this is the maximum allowable time from
the start of a power cycle to the time a
valid position fix is obtained. If no fix is
Table 19: Development Data On/Off Example
MaxAcqTime
(1000 -
2147483000)
mS
obtained in this time, the receiver is
deactivated for up to MaxOffTime, and a
hot start is commanded when the receiver
reactivates. The integer must be in
multiples of 1000mS.
The longest period (in mS) for which the
30000
receiver deactivates due to the
MaxOffTime
(1000 -
1800000)
mS
MaxAcqTime timeout. The actual
deactivated period may be less if the user-
specified duty cycle (OnTime / LpInterval)
can be maintained.
Checksum
<CR> <LF>
*0E
End of message termination
Table 20: Power Management Command Example 1
The table below lists the possible values for the Mode section of this command.
Value
0
1
2
Description
Ask receiver to send current power mode
Set receiver to Full power mode
Set receiver to Adaptive Trickle Power mode
Table 21: Mode Values
Total ON time = OnTime + 160mS + time to process each active NMEA message at
the programmed baud rate (default 9600)
1. Default setting is full power; trickle power disabled.
Page 18
Page 19
相关PDF资料
RZE002P02TL MOSFET P-CH 20V 200MA EMT3
RZF020P01TL MOSFET P-CH 12V 2A TUMT3
RZF030P01TL MOSFET P-CH 12V 3A TUMT3
RZM002P02T2L MOSFET P-CH 20V 0.2A UMT6
RZQ045P01TR MOSFET P-CH 12V 4.5A TSMT6
RZQ050P01TR MOSFET P-CH 12V 5A TSMT6
RZR020P01TL MOSFET P-CH 12V 2A TSMT3
RZR040P01TL MOSFET P-CH 12V 4A TSMT3
相关代理商/技术参数
RXM-UHF 制造商:RADIOMETRIX 制造商全称:RADIOMETRIX 功能描述:UHF Radio Telemetry Receiver Module
RXP0005 制造商:Panasonic Industrial Company 功能描述:ARM
RXP0014 制造商:Panasonic Industrial Company 功能描述:PULLEY
RXP0015 制造商:Panasonic Industrial Company 功能描述:ROLLER
RXP0016 制造商:Panasonic Industrial Company 功能描述:ROLLER
RXP0016-4 制造商:Panasonic Industrial Company 功能描述:ROLLER
RXP0017 制造商:Panasonic Industrial Company 功能描述:ROLLER
RXP0017-3 制造商:Panasonic Industrial Company 功能描述:ROLLER